Applicable Scenes:
They are suitable for occasions such as city special charging stations that provide charging for bus, taxi, public service vehicles, sanitation vehicles,logistics vehicles, etc.; city public charging stations that provide charging for private cars, commuter, bus; intercity highway charging stations and other occasions that need special DC fast charging.
Features:
Delicate appearance, simple operation, convenient installation;
High efficiency, reliable and stable performance; Friendly interaction interface, 4.3-inch color touch screen; Support Plug&Play;
Overload integrated Protection;
Sr. NO. |
Parameters |
Requirements |
||
General Requirements |
||||
1 |
EV charger Type |
DC |
||
2 |
Charger Capacity |
7KW |
15KW |
20KW |
3 |
Model No. |
ENC-DCX007A ENC-DCB007A |
ENC-DCX015A ENC-DCB015A |
ENC-DCX020A ENC-DCB020A |
4 |
Mounting |
Portable/ Wall-mounted |
||
Input Requirements |
||||
5 |
AC Supply System |
Single-Phase |
3 Phase |
3 Phase |
6 |
Nominal Input voltage |
220V ± 15% |
380V ± 15% |
|
7 |
Input frequency |
50Hz, ±1.5Hz / 60Hz, ±1.5Hz |
||
Environmental Requirements |
||||
8 |
Ambient Temperature Range |
-25 to 55°C |
||
9 |
Ambient Humidity |
5 to 95% |
||
10 |
Storage temperature |
-40 to 70°C |
||
Mechanical Requirements |
||||
11 |
IP Ratings |
IP 54 |
||
12 |
Cooling |
Air cooled |
Forced air cooled |
|
Output Requirements |
||||
13 |
Number of outputs |
1 |
||
14 |
Type of each output |
200-750VDC(+20% and -20%) |
||
15 |
Output Current |
Max. 11Amp |
Max. 37.5Amp |
Max. 50Amp |
16 |
Power Factor |
=0.99(50% load above) |
||
User Interface & Display Requirements |
||||
17 |
Display |
Portable: LED Wall-mounted 4.3-inch touchscreen |
||
Communication Requirements |
||||
18 |
Communication between EVSE and Central Server |
Portable: / Wall-mounted: OCPP 1.6 protocol (optional) |
||
Protection & Safety Requirements |
||||
119 |
Safety Parameters |
Over current, under voltage, Residual current, Surge protection, leakage protection, Short circuit, Over temperature, etc. |
||
20 |
Power failure |
If there is a power failure, user is indicated about this. |