Applicable Scenes:
They are suitable for occasions such as city special chargingstations that provide charging for bus, taxi,public service vehicles, sanitation vehicles, logistics vehicles, etc.; city public charging stations that provide charging for private cars, commuter, bus;intercity highway charging stations and other occasions that need special AC fast charging.
Technical Data:
S. NO.td |
Parameters |
Requirements |
||
General Requirements |
||||
1 |
EV charger Type |
AC |
||
2 |
Charger Capacity |
7KW(Plug and play) |
7KW |
11KW |
3 |
Model No. |
ENC-ACL007A / ENC-ACB007A |
ENC-ACL007A / ENC-ACB007A |
ENC-ACL011A / ENC-ACB011A |
4 |
Mounting |
Column type/ Wall-mounted |
||
Input Requirements |
||||
5 |
AC Supply System |
Single-Phase, 3 Wire AC system |
Three-Phase, 5 Wire AC system |
|
6 |
Nominal Input voltage |
220V ± 15% |
380V ± 15% |
|
7 |
Input frequency |
50Hz, ±1.5Hz / 60Hz, ±1.5Hz |
||
Environmental Requirements |
||||
8 |
Ambient Temperature Range |
-25 to 55°C |
||
9 |
Ambient Humidity |
5 to 95% |
||
10 |
Storage temperature |
-40 to 70°C |
||
Mechanical Requirements |
||||
11 |
IP Ratings |
IP 54 |
||
12 |
Cooling |
Air cooled |
||
Output Requirements |
||||
13 |
Number of outputs |
1 |
||
14 |
Type of each output |
220V ± 15% single phase, 32Amp |
380V ± 15% three phase, 16Amp |
|
15 |
Output Current |
32 Amp |
16 Amp |
|
16 |
Output Connector Compatibility |
IEC-61851-22, IEC 62196-2 Mode 2, Type 2 |
||
User Interface & Display Requirements |
||||
17 |
Display & touch-screen size |
/ |
4.3 inches |
4.3 inches |
18 |
User Authentication |
Mobile application or User interface / QR Code/RFID Card /Password Login |
||
19 |
Metering Information |
Consumption Units |
||
Communication Requirements |
||||
20 |
Communication between EVSE and Central Server |
/ |
OCPP 1.6 protocol (optional) |
OCPP 1.6 protocol (optional) |
21 |
Interface between charger and CMS |
Ethernet and GPRS Modem |
||
Protection & Safety Requirements |
||||
22 |
Safety Parameters |
Over current, under voltage, Residual current, Surge protection, leakage protection, Short circuit, Over temperature, etc. |
||
23 |
Power failure |
If there is a power failure, user is indicated about this. |